Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorHeld, Martin
dc.contributor.authorWeiser, Werner
dc.contributor.authorWilhelmstötter, Franz
dc.contributor.editorSkala, Václav
dc.date.accessioned2013-04-19T10:17:35Z
dc.date.available2013-04-19T10:17:35Z
dc.date.issued2004
dc.identifier.citationJournal of WSCG. 2004, vol. 12, no. 1-3, p. 153-160.en
dc.identifier.issn1213-6972
dc.identifier.urihttp://wscg.zcu.cz/wscg2004/Papers_2004_Full/H61.pdf
dc.identifier.urihttp://hdl.handle.net/11025/1716
dc.description.abstractWe present a fully automatic scheme for the registration of MR images. The registration is carried out as a combination of an affine and an elastic transformation. The affine part is generated by means of an affine Principal Components Analysis (PCA), which is an extension of the standard rigid PCA. We use the affine PCA as a preparatory step to guarantee maximum spatial similarity for the subsequent elastic transformation. The elastic transformation itself is based on a displacement vector field generated by means of Monte Carlo methods. Contrary to other Monte Carlo methods that define feature boundaries based on the grey-value transition of adjacent pixels, we make use of more accurate feature boundaries segmented by means of statistical feature extraction methods. We also present a validation method for verifying the segmentation results for simulated MR images. Although discussed in the context of medical imaging, our approach can also be applied as a general-purpose registration method in other fields of image processing. We conclude this paper with a discussion of the results obtained.en
dc.format8 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUNION Agencycs
dc.relation.ispartofseriesJournal of WSCGen
dc.rights© UNION Agencycs
dc.subjectlékařské zobrazovánícs
dc.subjectmagnetická rezonancecs
dc.subjectMonte Carlocs
dc.subjectanalýza hlavních komponentcs
dc.titleFully automatic elastic registration of MR images with statistical feature extractionen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.subject.translatedmedical imagingen
dc.subject.translatedmagnetic resonanceen
dc.subject.translatedMonte Carloen
dc.subject.translatedprincipal component analysisen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Volume 12, number 1-3 (2004)

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
H61.pdf300,11 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/1716

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.