Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorStein, Zbigniew
dc.contributor.authorZielińska, Maria
dc.contributor.editorUlrych, Bohuš
dc.date.accessioned2017-04-03T09:03:02Z
dc.date.available2017-04-03T09:03:02Z
dc.date.issued2007
dc.identifier.citationAMTEE ’07 : seventh international conference on Advanced Methods in the Theory of Electrical Engineering : September 10-12, 2007 [Pilsen, Czech Republic].en
dc.identifier.isbn978-80-7043-564-9
dc.identifier.urihttp://amtee.zcu.cz/AMTEE/ArchivedProceedings/proceedings_AMTEE_2007/data/section_i.html
dc.identifier.urihttp://hdl.handle.net/11025/25814
dc.format7 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherUniversity of West Bohemiaen
dc.rights© University of West Bohemiaen
dc.subjectelektrické strojecs
dc.subjectsynchronní generátorcs
dc.subjectasymetrie proudůcs
dc.subjectasymetrické zatížení generátorůcs
dc.titleSelected problems of autonomic operation of three-phase synchronous generatorsen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe paper presents selected problems related to autonomous operation of three-phase synchronous generators used in diesel-electric sets appropriated to emergency supply of various receivers of electric power located in stationary, communal, or industrial objects in case of failure of the basic electric power supply. A set of equations adapted to analysing the conditions of autonomous operation of three-phase synchronous generators is presented (in the conditions defined by means of computer simulations). The equations are presented in the form enabling analysis of the operation conditions of the generators driven by combustion engines of oscillating rotational speeds that, inducing variations of the frequencies of induced electromagnetic forces. The equations are so formulated as to allow for analysing operation of the generators under various operation conditions, particularly forced by asymmetric impedances of the receivers. The equations enable analysis of non-symmetric conditions of the generator operation states, among others, in the cases like single-phase asymmetric loads or internal asymmetry giving rise to electromotive forces of symmetric components of negative and zero sequence. The equations enable calculating the active and reactive power delivered by the generators under various frequency values and asymmetric conditions. The formulated equations were used for calculating characteristic parameters of generators under various operation conditions.en
dc.subject.translatedelectrical machinesen
dc.subject.translatedsynchronous generatoren
dc.subject.translatedasymmetry of currentsen
dc.subject.translatedasymmetric loads of generatorsen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:CPEE – AMTEE 2007