Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Tomášek, Michal | |
dc.contributor.author | Matas, Richard | |
dc.contributor.author | Syka, Tomáš | |
dc.date.accessioned | 2018-04-04T09:03:52Z | - |
dc.date.available | 2018-04-04T09:03:52Z | - |
dc.date.issued | 2017 | |
dc.identifier.citation | TOMÁŠEK, M., MATAS, R., SYKA, T. The analysis of the flow with water injection in a centrifugal compressor stage using CFD simulation. In 36th Meeting of Departments of Fluid Mechanics and Thermodynamics. NY: American Institute of Physics Publishing, 2017. s. 1-5. ISBN 978-0-7354-1572-0 , ISSN 0094-243X. | en |
dc.identifier.isbn | 978-0-7354-1572-0 | |
dc.identifier.issn | 0094-243X | |
dc.identifier.uri | 2-s2.0-85030770408 | |
dc.identifier.uri | http://hdl.handle.net/11025/29497 | |
dc.description.abstract | Článek se zabývá principem přímého chlazení stlačovaného plynu v odstředivém kompresoru na základě odpařování přidané tekuté fáze v kanále za oběžným kolem. Snížení teploty plynu je dosaženo tím, že se získá teplo potřebné pro odpařování kapalné fáze. Vliv přídavné kapalné fáze na parametry proudového pole se porovnává s ideální simulací plynu ve vymezené oblasti a se stejnými okrajovými podmínkami. | cs |
dc.format | 5 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | American Institute of Physics Publishing | en |
dc.relation.ispartofseries | 36th Meeting of Departments of Fluid Mechanics and Thermodynamics | en |
dc.rights | Plný text není přístupný. | cs |
dc.rights | © American Institute of Physics Publishing | en |
dc.subject | přímé chlazení | cs |
dc.subject | CFD simulace | cs |
dc.subject | radiální kompresor | cs |
dc.title | Analýza dvoufázového proudění v průtočné části radiálního kompresoru | cs |
dc.title | The analysis of the flow with water injection in a centrifugal compressor stage using CFD simulation | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | closedAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | The article deals with the principle of direct cooling of the pressure gas in a centrifugal compressor based on evaporation of the additional fluid phase in a control domain. A decrease of the gas temperature is reached by taking the heat, which is required for evaporation of the fluid phase. The influence of additional fluid phase on the parameters of the multiphase flow is compared with the ideal gas simulation in the defined domain and with the same boundary conditions. | en |
dc.subject.translated | direct cooling | en |
dc.subject.translated | CFD simulation | en |
dc.subject.translated | radial compressor | en |
dc.identifier.doi | 10.1063/1.5004378 | |
dc.type.status | Peer-reviewed | en |
dc.identifier.document-number | 417391000044 | |
dc.identifier.obd | 43921605 | |
dc.project.ID | SGS-2016-045/Zvyšování účinnosti, spolehlivosti a životnosti energetických strojů a zařízení 4 | cs |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference papers (MIS) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
1.5004378_Matas.pdf | 405,91 kB | Adobe PDF | Zobrazit/otevřít Vyžádat kopii |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/29497
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.