Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorChvostová, Eva
dc.contributor.authorKonopík, Pavel
dc.contributor.authorHorváth, Pavel
dc.contributor.editorKučerová, Ludmila
dc.contributor.editorJirková, Hana
dc.contributor.editorJeníček, Štěpán
dc.date.accessioned2019-10-08T12:14:01Z-
dc.date.available2019-10-08T12:14:01Z-
dc.date.issued2019
dc.identifier.citationJIRKOVÁ, Hana ed.; JENÍČEK, Štepán ed. Proceedings PING 2019: modern trends in material engineering: 10.-13.09.2019, Pilsen. 1. vyd. Plzeň: University of West Bohemia, 2019, s. 68. ISBN 978-80-261-0879-5.en
dc.identifier.isbn978-80-261-0879-5
dc.identifier.urihttp://hdl.handle.net/11025/35246
dc.description.sponsorshipPING 2019 is organized with the support of funds for specific university research project SVK1-2019-002.en
dc.format1 s.cs
dc.format.mimetypeapplication/PDF
dc.language.isoenen
dc.publisherUniversity of West Bohemiaen
dc.rights© University of West Bohemiaen
dc.subjectexpoziční zařízenícs
dc.subjectminiaturizované zkušební vzorkycs
dc.subjectdegradace materiálucs
dc.titleOptimization of test specimen dimensions for thermal power station exposure deviceen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedDegradation of metallic materials can decrease mechanical properties of metal constructions and components in thermal power plants during their operation and consequently lead to loss of safety and reliability. It is difficult to remove material from the pressure system of the equipment being operated. Therefore, the effort is to design, produce and subsequently install exposure channels, which will allow to remove and evaluate samples of exposed material without intervention into the pressure system. The exposure device for pressures and steam temperature in supercritical blocks, which would contain sufficient test material to produce conventional test specimens, is unrealistic in size, energy and economics. The way is to optimize the dimensions of the exposure device according to the miniaturized test specimens, which, in addition to the tensile test and the structural evaluation, can also carry out other required tests, such as bending impact tests with transition temperature, fracture toughness and fatigue tests. This paper deals with optimization of test specimens for the internal dimensions of the exposure device and shows the applicability of small sample methodologies for selected materials.en
dc.subject.translatedexposure deviceen
dc.subject.translatedminiaturized test specimensen
dc.subject.translatedmaterial degradationen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Proceedings PING 2019: modern trends in material engineering
Proceedings PING 2019: modern trends in material engineering

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
Chvostova.pdfPlný text184,69 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/35246

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.