Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorPančík, Juraj
dc.contributor.authorKukučka, Marek
dc.contributor.editorPinker, Jiří
dc.date.accessioned2019-10-08T12:54:17Z
dc.date.available2019-10-08T12:54:17Z
dc.date.issued2016
dc.identifier.citation2016 International Conference on Applied Electronics: Pilsen, 6th – 7th September 2016, Czech Republic, p.195-200.en
dc.identifier.isbn978–80–261–0601–2 (Print)
dc.identifier.isbn978–80–261–0602–9 (Online)
dc.identifier.issn1803–7232 (Print)
dc.identifier.issn1805–9597 (Online)
dc.identifier.urihttp://hdl.handle.net/11025/35259
dc.format6 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherZápadočeská univerzita v Plznics
dc.rights© Západočeská univerzita v Plznics
dc.subjectdetektory zářenícs
dc.subjectserverycs
dc.subjectIP networkscs
dc.subjectprotokolycs
dc.subjecttestovánícs
dc.subjectúnavacs
dc.subjectdatabázecs
dc.titleInternet protocol based digital counters for legacy fatigue testing machinesen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedIn presented paper we describe a design and implementation of an information system based on base of embedded client and Linux application server architecture. Presented information system serves for remote collection, storing and processing information on the number of carried out mechanical cycles for group of older existing fatigue test machines in an automotive components production. This upgrade of existing infrastructure we built on the electronic counter module with Ethernet interface and on the known Internet Protocol (SNMP). Eight electronic counter modules replaced existing electromechanical digital totalizing counters and they count of outputs from 8 pieces of mechanical impulse test machines (each of them with 2Hz output frequency). The web and application servers are built on the Linux operating system. The MVC architecture (Model-View-Controller) serves as the base for web application and it was written together with backend application server around the Ruby on Rails web framework. The database is built on the MySQL server. We carried out three ways to verify of accuracy of this manner counting and collecting of mechanical cycles and we reached results comparable with manual collecting of data. Thanks to automatic detection of ends of fatigue tests we reached more effective utilization of test machines (more than 25%). Our solution of upgrading of the existing industrial infrastructure for fatigue tests is very reasonably priced and is suitable for older industrial facilities.en
dc.subject.translatedradiation detectorsen
dc.subject.translatedserversen
dc.subject.translatedIP networksen
dc.subject.translatedprotocolsen
dc.subject.translatedtestingen
dc.subject.translateddatabasesen
dc.subject.translatedfatigueen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Applied Electronics 2016
Applied Electronics 2016

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
PANČÍK.pdfPlný text537,92 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/35259

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.