Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Jílek, Jiří | |
dc.contributor.author | Štork, Milan | |
dc.contributor.editor | Pinker, Jiří | |
dc.date.accessioned | 2019-10-15T09:39:59Z | |
dc.date.available | 2019-10-15T09:39:59Z | |
dc.date.issued | 2017 | |
dc.identifier.citation | 2017 International Conference on Applied Electronics: Pilsen, 5th – 6th September 2017, Czech Republic, p.65-68. | en |
dc.identifier.isbn | 978–80–261–0641–8 (Print) | |
dc.identifier.isbn | 978–80–261–0642–5 (Online) | |
dc.identifier.issn | 1803–7232 (Print) | |
dc.identifier.issn | 1805–9597 (Online) | |
dc.identifier.uri | http://hdl.handle.net/11025/35410 | |
dc.format | 4 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | Západočeská univerzita v Plzni | cs |
dc.rights | © Západočeská univerzita v Plzni | cs |
dc.subject | systolické časové intervaly | cs |
dc.subject | LVET | cs |
dc.subject | měření pulsu se zápěstním tlakoměrem | cs |
dc.subject | Bland-Altmanův diagram | cs |
dc.subject | zdvihový objem | cs |
dc.title | Assessing left ventricular ejection time from wrist cuff pulse waveforms: Algorithm and evaluation | en |
dc.type | konferenční příspěvek | cs |
dc.type | conferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | Left ventricular ejection time (LVET) is an important component of systolic time intervals. It has been used as a surrogate for left ventricular contractility and stroke volume. We developed a method for the assessment of LVET from wrist cuff pulse waveforms. The waveforms are obtained from a partially inflated cuff held at the level of the heart. Each test involved acquisition of 10 second sample of waveform data. The data were processed after each test by specially developed software algorithm. Thirty tests were evaluated and compared with predicted values. The results showed the mean value of computed LVET equal to 309 ms and mean value of predicted LVET equal to 304 ms. We concluded that our method has the potential for use as a stand-alone method for evaluation of left ventricular contractility and for the determination of stroke volume. | en |
dc.subject.translated | systolic time intervals | en |
dc.subject.translated | left ventricular ejection time | en |
dc.subject.translated | wrist cuff pulse waveforms | en |
dc.subject.translated | Bland-Altman plot | en |
dc.subject.translated | stroke volume | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Applied Electronics 2017 Applied Electronics 2017 |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Jilek.pdf | Plný text | 187,7 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/35410
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.