Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Sorokina, Kristina | |
dc.contributor.author | Bušek, David | |
dc.contributor.author | Dušek, Karel | |
dc.contributor.editor | Pihera, Josef | |
dc.contributor.editor | Steiner, František | |
dc.date.accessioned | 2020-02-25T07:27:18Z | |
dc.date.available | 2020-02-25T07:27:18Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Electroscope. 2019, č. 2. | cs |
dc.identifier.issn | 1802-4564 | |
dc.identifier.uri | http://147.228.94.30/images/PDF/Rocnik2019/Cislo2_2019/r13c2c16.pdf | |
dc.identifier.uri | http://hdl.handle.net/11025/36515 | |
dc.format | 5 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | Západočeská univerzita v Plzni, Fakulta elektrotechnická | cs |
dc.rights | Copyright © 2019 Electroscope. All Rights Reserved. | en |
dc.subject | roztok NaCl | cs |
dc.subject | kapka vody | cs |
dc.subject | elektrochemická migrace | cs |
dc.subject | bezolovnaté pájky | cs |
dc.title | Electrochemical migration of lead-free solders and Ag-based electrically conductive adhesives in NaCl solution | en |
dc.type | článek | cs |
dc.type | article | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | In this article, the electrochemical migration of lead-free solders and electrically conductive adhesives with an Ag content of more than 70% was studied by using a water drop test in NaCl solution. The results of solder pastes were compared with the results of electrically conductive adhesives. It was found that some solder pastes with a low Ag content have a lower susceptibility to electrochemical migration than, for example, solder paste Sn42Bi58. The highest resistance to corrosion has a conductive adhesive CRM-1033B with an Ag content of 75%. Resistance and voltage during the water drop test. From the measured values, it was determined that the values of resistance and voltage decrease with dendrite growing. X-ray spectroscopy was also performed to determine the chemical elemental composition of dendrites. It was found that the dominant element of the dendrite of solder pastes was Sn. In the case of electrically conductive adhesives, Ag was the main element of the dendrite. | en |
dc.subject.translated | NaCl solution | en |
dc.subject.translated | water drop | en |
dc.subject.translated | electrochemical migration | en |
dc.subject.translated | lead-free solders | en |
dc.type.status | Peer-reviewed | en |
Vyskytuje se v kolekcích: | Číslo 2 (2019) Číslo 2 (2019) |
Soubory připojené k záznamu:
Soubor | Popis | Velikost | Formát | |
---|---|---|---|---|
Sorokina.pdf | Plný text | 615,55 kB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/36515
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.