Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorWang, Meng-Hui
dc.contributor.authorHsieh, Meng-Ju
dc.contributor.authorLu, Shiue-Der
dc.contributor.authorYe, Guang-Ci
dc.contributor.authorYu, Kuo-Nan
dc.contributor.authorLai, Hsiang-Yueh
dc.contributor.editorPinker, Jiří
dc.date.accessioned2019-10-17T05:55:07Z
dc.date.available2019-10-17T05:55:07Z
dc.date.issued2017
dc.identifier.citation2017 International Conference on Applied Electronics: Pilsen, 5th – 6th September 2017, Czech Republic, p.273-278.en
dc.identifier.isbn978–80–261–0641–8 (Print)
dc.identifier.isbn978–80–261–0642–5 (Online)
dc.identifier.issn1803–7232 (Print)
dc.identifier.issn1805–9597 (Online)
dc.identifier.urihttp://hdl.handle.net/11025/35452
dc.format5 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherZápadočeská univerzita v Plznics
dc.rights© Západočeská univerzita v Plznics
dc.subjectmetoda detekce synchronizace chaosucs
dc.subjectdiagnostika poruchycs
dc.subjectpartial dischargecs
dc.subjectvýkonové kondenzátorycs
dc.titleUsing chaos eye method to diagnose power capacitorsen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThis study focused on the measurement and diagnostic analysis of partial discharge in power capacitors operating under prolonged periods of high voltage. An off-line test was conducted on two power capacitors, which were subjected to defect preprocessing before the experiment. The partial discharge test of the terminal to the outer casing was carried out using a 24kV high voltage transformer. The voltage of the power discharge, after which the voltage signals of the test voltage and the partial discharge were extracted. The characteristics of the discharge signal were identified using an oscilloscope. The chaos synchronization detection method was then employed to establish a chaotic error scatter plot for the discharge voltage he gravity (chaos eye) of the error scatter plot was used as the fault diagnosis feature. The advantage of this approach was the drastic reduction of the amount of data for feature extraction, and the effective detection of the slight discharge signal variation in power capacitors, thereby anticipating their operation and enabling the implementation of preemptive contingency measures to avoid major accidents.en
dc.subject.translatedchaos synchronization detection methoden
dc.subject.translatedfault diagnosisen
dc.subject.translatedpartial dischargeen
dc.subject.translatedpower capacitatorsen
dc.type.statusPeer-revieweden
Vyskytuje se v kolekcích:Applied Electronics 2017
Applied Electronics 2017

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
Wang.pdfPlný text991,32 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/35452

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.