dc.contributor.authorLezhniuk, Petr
dc.contributor.authorKomar, Vyacheslav
dc.contributor.authorRubanenko, Olena
dc.contributor.authorOstra, Natalia
dc.date.accessioned2020-11-30T11:00:13Z
dc.date.available2020-11-30T11:00:13Z
dc.date.issued2020
dc.identifier.citationLEZHNIUK, P., KOMAR, V., RUBANENKO, O., OSTRA, N. The sensitivity of the process of optimal decisions making in electrical networks with renewable energy sources. Przeglad Elektrotechniczny, 2020, roč. 96, č. 10, s. 32-38. ISSN 0033-2097.cs
dc.identifier.issn0033-2097
dc.identifier.uri2-s2.0-85092178904
dc.identifier.urihttp://hdl.handle.net/11025/42219
dc.format7 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherWydawnictwo SIGMApl
dc.relation.ispartofseriesPrzeglad Elektrotechnicznypl
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Wydawnictwo SIGMApl
dc.titleThe sensitivity of the process of optimal decisions making in electrical networks with renewable energy sourcesen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedAre showed the necessity of the functioning of control automatization systems of conditions of bulk power system with renewable energy sources (RES) by taking into account the sensitivity. It is advisable to carry out optimal control of the bulk power system by introducing control parameters into the optimality (insensitivity) area. The permissible deviation range of the control parameters from their optimal values is determined by the solution of the direct and reverse sensitivity of the task. The direct and indirect tasks of the sensitivity can and should be solved in relative units using similarity theory methods. Showed that in this case the limits of the permissible optimality range are determined analytically. Comparing the allowable values of the optimality of the individual control parameters, it is possible to rank them and set the appropriate order and intensity of their actions. This makes it possible to compensate for the disturbances in the bulk power system that are carried out due to the instability of RES generation, in the most rational way.en
dc.subject.translatedbulk power systemen
dc.subject.translatedrenewable energyen
dc.subject.translatedautomated control systemen
dc.subject.translatedsensitivityen
dc.subject.translatedtheory of similarityen
dc.subject.translatedrelative unitsen
dc.identifier.doi10.15199/48.2020.10.05
dc.type.statusPeer-revieweden
dc.identifier.document-number576255500005
dc.identifier.obd43930862
Appears in Collections:Články / Articles (RICE)
OBD

Files in This Item:
File SizeFormat 
Rubanenko_The sensitivity_5.pdf386,24 kBAdobe PDFView/Open    Request a copy


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/42219

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD