Full metadata record
DC FieldValueLanguage
dc.contributor.authorSuchý, Ondřej
dc.contributor.authorJanouš, Štěpán
dc.contributor.authorTalla, Jakub
dc.contributor.authorPeroutka, Zdeněk
dc.date.accessioned2021-03-15T11:00:30Z-
dc.date.available2021-03-15T11:00:30Z-
dc.date.issued2020
dc.identifier.citationSUCHÝ, O. JANOUŠ, Š. TALLA, J. PEROUTKA, Z.Torque ripple minimization in PMSM drive with non-sinusoidal back EMF using model predictive control. In: Proceedings of the 2020 19th International Conference on Mechatronics - Mechatronika (ME 2020). Piscataway: IEEE, 2020. s. 78-82. ISBN 978-1-72815-602-6.cs
dc.identifier.isbn978-1-72815-602-6
dc.identifier.uri2-s2.0-85099305090
dc.identifier.urihttp://hdl.handle.net/11025/42950
dc.format5 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherIEEEen
dc.relation.ispartofseriesProceedings of the 2020 19th International Conference on Mechatronics - Mechatronika (ME 2020)en
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© IEEEen
dc.titleTorque ripple minimization in PMSM drive with non-sinusoidal back EMF using model predictive controlen
dc.typekonferenční příspěvekcs
dc.typeconferenceObjecten
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedA conventional field oriented control (FOC) relies on park transform and sinusoidal back EMF, in order to tread harmonic signals as constants. As a consequence, resulting control structure based on linear PI controllers is very simple and well tested. However if the back EMF of the machine is not sinusoidal, single coordinated dq system fails to adequately describe the motor, which negatively impacts the control performance and causes additional torque ripple and joule losses in the motor. A commonly used methods for compensation of negative effects of non-sinusoidal back EMF significantly increase the complexity of the algorithm. In this paper we use popular version of predictive control called FCS-MPC which does not relies on the park transform, and thus it allows to address this issue in a simple way. The algorithm has been tested in simulations using the real data of target permanent magnet synchronous motor (PMSM) drive of rated power 100kW.en
dc.subject.translatednon-sinusoidal back-EMFen
dc.subject.translatedpredictive controlen
dc.subject.translatedminimization torque rippleen
dc.subject.translatedPMSMen
dc.identifier.doi10.1109/ME49197.2020.9286703
dc.type.statusPeer-revieweden
dc.identifier.obd43931416
dc.project.IDSGS-2018-009/Výzkum a vývoj perspektivních technologií v elektrických pohonech a strojích IIIcs
Appears in Collections:Konferenční příspěvky / Conference Papers (KEV)
Konferenční příspěvky / Conference papers (RICE)
OBD

Files in This Item:
File SizeFormat 
Suchy_ME.pdf390,42 kBAdobe PDFView/Open    Request a copy


Please use this identifier to cite or link to this item: http://hdl.handle.net/11025/42950

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

search
navigation
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD