Název: Interactive Radial Volume Histogram Stacks for Visualization of Kidneys from CT and MRI
Autoři: Selver, M. Alper
Merve, Özdemir
Selvi, Eşref
Citace zdrojového dokumentu: WSCG 2013: Full Papers Proceedings: 21st International Conference in Central Europe on Computer Graphics, Visualization and Computer Vision in cooperation with EUROGRAPHICS Association, p. 233-242.
Datum vydání: 2013
Nakladatel: Václav Skala - UNION Agency
Typ dokumentu: konferenční příspěvek
conferenceObject
URI: http://wscg.zcu.cz/WSCG2013/!_2013-WSCG-Full-proceedings.pdf
http://hdl.handle.net/11025/10615
ISBN: 978-80-86943-74-9
Klíčová slova: přenosové funkce;objemové vykreslování;lékařská vizualizace;ledvina
Klíčová slova v dalším jazyce: transfer functions;volume rendering;medical visualization;kidney
Abstrakt: Optical parameter assignment via Transfer Functions (TF) is the sole interactive part in medical visualization via volume rendering. Being an interactive element of the rendering pipeline, TF specification has very important effects on the quality of volume-rendered medical images. However, TF specification should be supported by informative search spaces, interactive data exploration tools and intuitive user interfaces. Due to the trade-off between user control and TF domain complexity, integrating different features into the TF without losing user interaction is a challenging task since both are needed to fulfill the expectations of a physician. By addressing this problem, we introduce a semi-automatic method for initial generation of TFs. The proposed method extends the concept of recently introduced Volume Histogram Stack (VHS), which is a new domain constructed by aligning the histograms of the image slices of a CT and/or MR series. In this study, the VHS concept is extended by allowing the user to define an alignment axis using orthogonal multi planar reconstructions via simple, yet effective, interaction mechanisms. The construction of VHS according to the slices generated specifically for user defined search space allows the more informative integration of local intensity distribution, and better spatial positioning of the organ of interest into the TF. For testing, the proposed strategy is applied to kidney visualization from CT and MRI series. The performance of extended VHS domain is evaluated via intensity based TF design. Volumetric histogram based manual TF specifications are quantitatively compared to VHS based manual tweaking of original slices, and to extended-VHS based automatic TF design. The results show both quantitatively and qualitatively enhanced rendering quality for kidney visualization.
Práva: © Václav Skala - UNION Agency
Vyskytuje se v kolekcích:WSCG 2013: Full Papers Proceedings

Soubory připojené k záznamu:
Soubor Popis VelikostFormát 
Selver.pdfPlný text1,14 MBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/10615

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.