Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorHolík, Michael
dc.contributor.authorAhmadov, G.
dc.contributor.authorBerikov, D.
dc.contributor.authorAhmadov, F.
dc.contributor.authorKopatch, Yu.
dc.contributor.authorNuruyev, S.
dc.contributor.authorAkbarov, R.
dc.contributor.authorAbbaszada, N.
dc.contributor.authorTelezhnikov, S.
dc.contributor.authorBroulím, Jan
dc.contributor.authorŠiroký, J.
dc.contributor.authorMora Sierra, Yesid
dc.date.accessioned2019-02-11T11:00:15Z-
dc.date.available2019-02-11T11:00:15Z-
dc.date.issued2018
dc.identifier.citationHOLÍK, M., AHMADOV, G., BERIKOV, D., AHMADOV, F., KOPATCH, Y., NURUYEV, S., AKBAROV, R., ABBASZADA, N., TELEZHNIKOV, S., BROULÍM, J., ŠIROKÝ, J., MORA SIERRA, Y. A synchronization and data acquisition system for silicon detectors. Journal of Instrumentation, 2018, roč. 13, č. November, s. 0-8. ISSN 1748-0221.en
dc.identifier.issn1748-0221
dc.identifier.uri2-s2.0-85057599291
dc.identifier.urihttp://hdl.handle.net/11025/30926
dc.format9 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherIOP Publishingen
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© IOP Publishingen
dc.titleA synchronization and data acquisition system for silicon detectorsen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedA dedicated synchronization bus has been developed and integrated into the FITPix COMBO device. It can be used as Timepix read-out (involving back-side-pulse acquisition) or as a simple spectrometer device—Spectrig (when an external single pad sensor is connected, e.g. Δ E detector). The synchronization bus permits the implementation of a system of up to 32 distinct devices running in clock locked mode while the absolute value of the timestamp is distributed to all devices in the system. Any combination of Timepix or spectrometer devices (up to 32) can be connected-up to create a final measurement set-up. The synchronization bus has also been designed to control a trigger signal and busy signal to allow an effective filtration of unpaired events when coincidence measurement is performed. The system has been tested with a Δ E− E telescope consisting of a thin detector and Timepix. The thin detector has been used for Δ E and the Timepix detector for E measurements. The Δ E detector has an area of 10×10 mm2 and a thickness of 12 μm with non-uniformity of 8%. The area and thickness of Timepix are 14×14 mm2 and 300 μm, respectively. The detection system can provide simultaneous information about position, energy, time and type of registered particles with high synchronization accuracy. Test measurements have been carried out with an alpha particle source (Ra-226) in a vacuum and the results of these measurements are presented in this paper.en
dc.subject.translatedinstrumentation and methods for heavy-ion reactions and fission studiesen
dc.subject.translatedion identification systemsen
dc.subject.translateddata acquisition conceptsen
dc.subject.translatedtrigger concepts and systems (hardware and software)en
dc.identifier.doi10.1088/1748-0221/13/11/C11019
dc.type.statusPeer-revieweden
dc.identifier.document-number451408400001
dc.identifier.obd43924071
dc.project.IDEF16_019/0000766/Inženýrské aplikace fyziky mikrosvětacs
dc.project.IDSGS-2018-001/Výzkum a vývoj elektronických a komunikačních systémů ve vědeckých a inženýrských aplikacíchcs
dc.project.IDTE01020455/Centrum pokročilých jaderných technologií (CANUT)cs
Vyskytuje se v kolekcích:Články / Articles (KAE)
Články / Articles (RICE)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Holik_2018_JINST_13_C11019.pdf718,45 kBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/30926

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD