Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorSedlák, Petr
dc.contributor.authorKuberský, Petr
dc.contributor.authorMívalt, Filip
dc.date.accessioned2019-03-04T11:50:36Z-
dc.date.available2019-03-04T11:50:36Z-
dc.date.issued2019
dc.identifier.citationSEDLÁK, P., KUBERSKÝ, P., MÍVALT, F. Effect of various flow rate on current fluctuations of amperometric gas sensors. Sensors and Actuators. B, Chemical, 2019, roč. 283, č. 15 March, s. 321-328. ISSN 0925-4005.en
dc.identifier.issn0925-4005
dc.identifier.uri2-s2.0-85058367092
dc.identifier.urihttp://hdl.handle.net/11025/31158
dc.format8 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherElsevieren
dc.rightsPlný text je přístupný v rámci univerzity přihlášeným uživatelům.cs
dc.rights© Elsevieren
dc.titleEffect of various flow rate on current fluctuations of amperometric gas sensorsen
dc.typečlánekcs
dc.typearticleen
dc.rights.accessrestrictedAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedThe flow rate of analyte is a key parameter in the measurement system that influences response of gas sensors. The paper focuses on possibility of improved gas detection by modulation of analyte flow rate around amperometric sensors at equilibrium conditions by studying the direct current level and its fluctuations at selected concentration. To independently explore an impact of concentration and flow rate on spectral density of current fluctuations, all measurements were provided out under the same temperature, and each sample sensor was put to the same position at the test chamber to be under same fluidic condition. The experiments were carried out on the fully-printed amperometric NO2 sensor based on a semi-planar three electrode topology. The aims of this experimental study are two-fold: firstly, to show that spectral density of current fluctuations significantly changes in the level and the shape as flow rate increases at constant concentration of detected gas; and secondly, to demonstrate that evaluation of these fluctuations and DC component can be used to compensate the negative effect of flow rate on sensor responses. The spectral density of current fluctuations develops as several mechanisms related to fluctuation phenomena become dominant with increasing flow rate. Thus, signal-to-noise ratio of current response on detected gas decreases as flow rate increases, while the ratio is almost invariant to gas concentration.en
dc.subject.translatedgas sensoren
dc.subject.translatedcurrent fluctuationsen
dc.subject.translatedflowen
dc.subject.translatedmodulationen
dc.subject.translatedamperometricen
dc.subject.translatedsignal-to-noise ratioen
dc.identifier.doi10.1016/j.snb.2018.12.006
dc.type.statusPeer-revieweden
dc.identifier.document-number455854000040
dc.identifier.obd43924383
dc.project.IDGA18-19104S/Vliv krystalinity polymerního elektrolytu a morfologie uhlíkové elektrody na transport elektrického náboje a jeho fluktuace v elektrochemických plynových senzorechcs
dc.project.IDLO1607/RICE-NETESIS - nové technologie a koncepce pro inteligentní průmyslové systémy (NETESIS)cs
Vyskytuje se v kolekcích:Články / Articles (KET)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
Kubersky_Sensor and Actuators.pdf2,1 MBAdobe PDFZobrazit/otevřít  Vyžádat kopii


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/31158

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD