Full metadata record
DC poleHodnotaJazyk
dc.contributor.authorSkřivanová, Nikola
dc.contributor.authorMelichar, Martin
dc.date.accessioned2022-03-07T11:00:22Z-
dc.date.available2022-03-07T11:00:22Z-
dc.date.issued2021
dc.identifier.citationSKŘIVANOVÁ, N. MELICHAR, M. EVALUATION OF EFFECT OF ATTRIBUTIVE MEASUREMENTS IN A CLIME COMPARTMENT ON THE VALUE OF DIMENSIONAL MEASUREMENT UNCERTAINTY IN AN ACCRETED TEST LABORATORY. In Proceedings of the 32nd International DAAAM Virtual Symposium ''Intelligent Manufacturing & Automation. Vienna: 978-3-902734-33-4, 2021. s. 289-293. ISBN: 978-3-902734-33-4 , ISSN: 1726-9679cs
dc.identifier.isbn978-3-902734-33-4
dc.identifier.issn1726-9679
dc.identifier.uri2-s2.0-85123942793
dc.identifier.urihttp://hdl.handle.net/11025/47082
dc.format5 s.cs
dc.format.mimetypeapplication/pdf
dc.language.isoenen
dc.publisherDAAAM International Viennaen
dc.relation.ispartofseriesProceedings of the 32nd International DAAAM Virtual Symposium ''Intelligent Manufacturing & Automationen
dc.rights© DAAAMen
dc.titleEVALUATION OF EFFECT OF ATTRIBUTIVE MEASUREMENTS IN A CLIME COMPARTMENT ON THE VALUE OF DIMENSIONAL MEASUREMENT UNCERTAINTY IN AN ACCRETED TEST LABORATORYen
dc.typekonferenční příspěvekcs
dc.typeConferenceObjecten
dc.rights.accessopenAccessen
dc.type.versionpublishedVersionen
dc.description.abstract-translatedIn the field of precision measurement and testing by state-accredited laboratories, the area of measurement uncertainty has a clear and indispensable role. This article builds on a 2018 study (The Influence of Humidity on ABS Plastic Measurement Result). This study addressed the variability in results occurring with changes in otherwise constant humidity in an accredited testing laboratory. This paper builds on the results obtained and evaluates the effect on the components of the standard uncertainty of the Type A measurement and the uncertainty of the Type B measurement). In order to understand the milestones of the process and their limitations. An analysis of the measurement system according to the VDA5 methodology was carried out and a clear limit was established beyond which the resulting values are no longer reliable. The results will lead to an increase in the relevance and accuracy of the measurements and the awareness of the professional metrology community.en
dc.subject.translatedmetrologyen
dc.subject.translateduncertaintyen
dc.subject.translatedmeasurementen
dc.subject.translatedattributiveen
dc.subject.translatedclime compartmenten
dc.identifier.doi10.2507/32nd.daaam.proceedings.041
dc.type.statusPeer-revieweden
dc.identifier.obd43934590
dc.project.IDSGS-2019-008/Výzkum a vývoj pro inovace v oboru strojírenská technologie - technologie obrábění III.cs
Vyskytuje se v kolekcích:Konferenční příspěvky / Conference papers (KTO)
OBD

Soubory připojené k záznamu:
Soubor VelikostFormát 
041_DAAAM_Srivanova_Melichar.pdf946,66 kBAdobe PDFZobrazit/otevřít


Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam: http://hdl.handle.net/11025/47082

Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.

hledání
navigace
  1. DSpace at University of West Bohemia
  2. Publikační činnost / Publications
  3. OBD