Full metadata record
DC pole | Hodnota | Jazyk |
---|---|---|
dc.contributor.author | Hruška, Karel | |
dc.contributor.author | Dvořák, P. | |
dc.date.accessioned | 2022-12-19T11:00:10Z | - |
dc.date.available | 2022-12-19T11:00:10Z | - |
dc.date.issued | 2022 | |
dc.identifier.citation | HRUŠKA, K. DVOŘÁK, P. Simplified Analytical Calculation of PM Machines Magnetic Flux Leakage Factor. In Proceedings : 2022 International Conference on Electrical Machines (ICEM 2022). Piscataway: IEEE, 2022. s. 1239-1245. ISBN: 978-1-66541-432-6 | cs |
dc.identifier.isbn | 978-1-66541-432-6 | |
dc.identifier.uri | 2-s2.0-85141052277 | |
dc.identifier.uri | http://hdl.handle.net/11025/50742 | |
dc.format | 7 s. | cs |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | en |
dc.publisher | IEEE | en |
dc.relation.ispartofseries | Proceedings : 2022 International Conference on Electrical Machines (ICEM 2022) | en |
dc.rights | © IEEE | en |
dc.title | Simplified Analytical Calculation of PM Machines Magnetic Flux Leakage Factor | en |
dc.type | konferenční příspěvek | cs |
dc.type | ConferenceObject | en |
dc.rights.access | openAccess | en |
dc.type.version | publishedVersion | en |
dc.description.abstract-translated | The permanent magnets used for generation of magnetic field in permanent magnet machines are placed in more or less magnetically conducting environment – electrical steel and air. This causes leakage of the magnetic flux from its desired path through the air gap. This paper describes simplified analytical calculation of magnetic properties of five most commonly used placements of permanent magnets and compares obtained leakage factors. A verification of the results via finite element method is also included. | en |
dc.subject.translated | electromagnetic modelling | en |
dc.subject.translated | finite element analysis | en |
dc.subject.translated | magnetic flux leakage | en |
dc.subject.translated | permanent magnets | en |
dc.identifier.doi | 10.1109/ICEM51905.2022.9910678 | |
dc.type.status | Peer-reviewed | en |
dc.identifier.obd | 43936926 | |
dc.project.ID | EF18_069/0009855/Elektrotechnické technologie s vysokým podílem vestavěné inteligence | cs |
dc.project.ID | SGS-2021-021/Výzkum a vývoj perspektivních technologií v elektrických pohonech a strojích IV | cs |
Vyskytuje se v kolekcích: | Konferenční příspěvky / Conference papers (RICE) OBD |
Soubory připojené k záznamu:
Soubor | Velikost | Formát | |
---|---|---|---|
Hruska_Simplified_Analytical_Calculation_of_PM_Machines_Magnetic_Flux_Leakage_Factor.pdf | 1,26 MB | Adobe PDF | Zobrazit/otevřít |
Použijte tento identifikátor k citaci nebo jako odkaz na tento záznam:
http://hdl.handle.net/11025/50742
Všechny záznamy v DSpace jsou chráněny autorskými právy, všechna práva vyhrazena.